MF 40 Pipe Repair Kit - measurement table

Measurement table

Amount of rolls and size
Nominal pipe diameter3,5 bar
(10 layers of wrapping)
10 bar
(15 layers of wrapping)
27,5 bar
(20+ layers of wrapping)
mm(mm x meters)
12,51 (50 x 1,5)1 (50 x 1,5)1 (50 x 1,5)
191 (50 x 1,5)1 (50 x 1,5)1 (50 x 1,5)
251 (50 x 1,5)1 (50 x 1,5)1 (50 x 3,6)
321 (50 x 1,5)1 (50 x 3,6)1 (50 x 3,6)
381 (50 x 1,5)1 (50 x 3,6)1 (50 x 3,6)
501 (50 x 3,6)1 (50 x 3,6)1 (50 x 3,6)
631 (50 x 3,6)1 (50 x 3,6)2 (50 x 3,6)
751 (50 x 3,6)1 (50 x 3,6)2 (50 x 3,6)
882 (75 x 2,7)2 (75 x 2,7)3 (75 x 2,7)
1002 (75 x 2,7)2 (75 x 2,7)3 (75 x 2,7)
1252 (75 x 2,7)3 (75 x 2,7)3 (75 x 2,7)
1502 (75 x 2,7)3 (75 x 2,7)4 (75 x 2,7)
2003 (75 x 2,7)4 (75 x 2,7)5 (75 x 2,7)
2503 (100 x 3,6)4 (100 x 3,6)5 (100 x 3,6)
3003 (100 x 3,6)4 (100 x 3,6)6 (100 x 3,6)
3504 (100 x 3,6)5 (100 x 3,6)7 (100 x 3,6)
4004 (100 x 3,6)6 (100 x 3,6)8 (100 x 3,6)
4504 (100 x 3,6)7 (100 x 3,6)9 (100 x 3,6)

Example: To repair a pipe 50mm in diameter designed to handle pressure of 3,5 bars, one 50 mm x 3,6 m Pipe Repair Kit (MF40-5036) is needed. At least 10 layers of Pipe Repair bandage need to be applied around the leak.

ATTENTION:

The measurement table serves only as a guideline. The product is applied manually and the result may vary depending on the experience of the person applying it. Always use the entire roll.

The table above is for standard pipe sizes. The actual diameter of the pipe may vary depending on its type and the thickness of its casing. When repairing a cased pipe refer to the values given for the next pipe diameter in the table. The application of this product on cased pipes may require the use of additional products.


See more...

General description of the Pipe Repair Kit

Instruction of the Pipe Repair Kit

Bureau Veritas (BV) Det Norske Veritas (DNV) Nippon Kaiji Kyokai (ClassNK) Lloyd's Register (LR) Korean Register (KR) China Classification Society (CCS) American Bureau of Shipping (ABS) Germanischer Lloyd (GL)